All claims made by manufacturer
COMPANY MODEL TYPE SPOT SIZE
Keeler Instruments Vantage Plus headmount with Intelligent optics:
Bulb Wireless exclusive headband small, medium,
Slimline dimmer control large
Keeler Instruments Vantage Plus headmount with Intelligent optics:
LED Wired exclusive headband small, medium,
dimmer control large
Keeler Instruments Vantage Plus headmount with Intelligent optics:
LED Wireless exclusive headband small, medium,
Standard dimmer control large
Keeler Instruments Vantage Plus headmount with Intelligent optics:
LED Wireless exclusive headband small, medium,
Slimline dimmer control large
Keeler Instruments Vantage Plus headmount with Intelligent optics:
LED Digital USB interface small, medium, large
Kowa/Neitz IO-Alpha small pupil small (19 mm);
med. (50 mm);
large (80 mm)
Kowa/Neitz IO-H BIO medium
Kowa/Neitz IO-TV video BIO; small;
small pupil medium;
large
Welch Allyn 12500 headmount small;
Binocular medium;
Indirect large
Welch Allyn 12500-D headmount small;
Binocular medium;
Indirect large
FIELD
COMPANY MODEL TYPE OF VIEW
Canon Medical CR-1 non-mydriatic digital 45°
Systems Mark II retina camera
Canon Medical CF-1 mydriatic digital 50°
Systems fundus camera
Canon Medical CX-1 hybrid mydriatic/non-mydriatic 50º (mydriatic)
Systems digital retinal camera 45º (non-myrdriatic)
Carl Zeiss FF450
Plus
full-feature fundus camera 50°, 30°, 20°
Meditec for color, red free, FA,
autofluorescence, and ICG.
Designed for digital interface.
Carl Zeiss VISUPAC Digital digital imaging and 50°, 30°, 20°
Meditec Imaging and Archive archive system
Management System
Carl Zeiss VISUCAM
PRO NM
non-mydriatic digital 45°, 30°
Meditec fundus camera
for color and red free
Carl Zeiss VISUCAM
NM/FA
non-mydriatic digital 45°, 30°
Meditec fundus camera for color,
red free and FA
Carl Zeiss VISUCAM
NM/FA FAF
non-mydriatic digital 45°, 30°
Meditec fundus camera for color,
red free, FA, autofluorescence
and ICG
Clarity Medical RetCam 3 digital: premature 30º, 80º, 120º,
Systems infant, children & 130º
adult anterior
chamber
Clarity Medical RetCam Shuttle digital: premature infant, 30º, 80º, 120º
Systems children & adult 130º
anterior chamber
Escalon Digital E5 digital conversion of any
Solutions mydriatic fundus
camera
BINOCULAR INDIRECTS
FILTERS POWER SOURCE PORTABILITY ADDITIONAL FEATURES
built-in UV/safety filter, slimline wireless - lithium polymer yes, w/wireless lithium IOS Optics w/single step spot & convergence for maximum 3D steropsis; hi-mag retinal
red-free, cobalt blue battery; comes with two batteries polymer battery lens to enhance visualization of fundus; PD range 52 mm-76 mm.
diffuser
built-in UV/safety filter, 3 options in 1: Smart Pack yes/Smart Pack LED illumination:10,000 hours of use; 17 hours of on time; IOS Optics w/single step
red-free, cobalt blue Convertible (mobile, wall or desk) spot & convergence for maximum 3D steropsis; hi-mag retinal lens to enhance visualization
diffuser or Wall Pack of fundus; PD range 52 mm-76 mm
built-in UV/safety filter, standard wireless lithium ion yes/wireless lithium ion LED illumination: 10,000 hours of use; 11 hours of on time; IOS optics with single
red-free; cobalt blue battery; comes with two batteries battery step spot & convergence of maximum 3D steropsis, hi-mag retinal lens
diffuser to enhance visualization of fundus. PD range 52 mm-76 mm.
built-in UV/safety filter, slimline wireless lithium polymer yes/wireless lithium LED illumination: 10,000 hours of use; 6 hours of on time; IOS optics with single step
red-free, cobalt blue battery; comes with two batteries polymer battery spot & convergence of maximum 3D steropsis, hi-mag retinal lens to enhance visualization
diffuser of fundus. PD range 52 mm-76 mm.
built-in UV/safety filter, red- wireless slimline polymer battery; yes/first digital ophthal- First digital binocular indirect system. Not old analog. Utilize Vantage Plus LED Digital Wireless
free, cobalt blue diffuser comes with two batteries moscope with USB interface in your office, operating room, and teaching facility or anywhere you want to capture digital images.
UV; blue; red-free opt. cordless rechargeable AC power wall- or Continuously adjustable observation angle; teaching mirror; video capability.
battery pack; carrying case desk-mount; portable,
rechargeable battery
blue; red-free opt. cordless rechargeable AC power wall- or Lightweight; halogen illumination.
battery pack; carrying case desk-mount; portable,
rechargeable battery
UV; blue; red-free requires AC power source for AC power wall- or Color CCD camera; continuous NTSC output.
CCD camera; carrying case desk-mount; portable,
rechargeable battery
cobalt blue or portable power pack; yes Video-aligned optics for crystal clear views; lightweight comfort; true small pupil
yellow; red-free wall- or desk-mount capability; UV/IR filter; 100 hrs. lamp life; widest PD range (49 mm to 74 mm),
leather padded headband.
diffuser; cobalt portable power pack; yes (w/portable Diffuser filter expands illuminated area; video-aligned optics; for crystal
blue or yellow; wall- or desk-mount power source) clear views; lightweight comfort; true small pupil capability; widest PD range
red-free (49 mm to 79 mm); leather-padded headband.
RETINAL CAMERAS
ANGIO- NUMBER/TYPE FLASH VIDEO
GRAPHY OF PORTS STIMULUS CAPACITY ADDITIONAL FEATURES
no digital n/a n/a Full 45-degree retinal images, 2x magnification, 1/4 flash intensinty of the CR-1, illuminated operation panel, Swivel,
5.7” LCD monitor, single joystick operation, 15.1 MP EOS digital SLR camera back, optional imageSPECTRUM software
and DICOM software.
yes digital n/a n/a Small-diameter mode; color photography; red free photography; fluorescein angiography (FA); proprietary control
software outputs retinal imaging information into optional imageSPECTRUM software; 10.1 MP EOS digital
SLR camera back; 2X magnification and DICOM software.
yes digital n/a n/a One touch selection between mydriatic and non-mydriatic mode; mydriatic and non-mydriatic fundus autofluorescence
(FAF) photography modes (color, red-free, fluorescein angiography, FAF, cobalt); EOS camera technology with 15.1 mega
pixels; 2X magnification; optional imageSPECTRUM software and DICOM software.
yes 2 main interface ports; 360 W/s yes High resolution ZEISS optics. Each angle of view has its own “telescope” lens to optimize image quality at all three
4 digital, video and/or Max magnifications; upper camera port optimized for digital interface. Fully integrated with VISUPAC Digital Imaging and Archive
film cameras possible Management System.
simultaneously
yes 4 digital sensors available; n/a import, store Digital Image Capture System based on relational database for complete image management, documentation,
USB and ethernet ports & play video progression viewing and image enhancement. Various high resolution digital sensor options and combinations.
Integrated report generator. Network ready and DICOM conform. VISUPAC comes with the onboard functionality to
connect to FORUM Data Management System. FORUM allows real-time viewing of reports or images from suppported
networked ZEISS and non-ZEISS instruments. FORUM supports bi-directional workflow for supported DICOM enabled
devices, reducing charting errors and increasing patient throughput.
no internal digital sensor; Xenon flash no All-integrated design with onboard database system. Auto-flash, auto-focus, 3.3mm small pupil mode, various preset
USB and ethernet ports lamp; 16 steps internal fixation points and stereo capture mode. Large LCD monitor for patient management; alignment, capture and
review. Network ready and DICOM conform. Telemedicine ready. VISUCAM comes with the onboard functionality to
connect to FORUM Data Management system. FORUM allows real-time viewing of reports or images from supported
networked ZEISS and non-ZEISS instruments. FORUM supports bi-directional workflow for supported DICOM enabled
devices, reducing charting errors and increasing patient throughput.
yes internal digital sensor; Xenon flash no All-integrated design with onboard database system. Auto-flash, auto-focus, 3.3mm small pupil mode, various preset
USB and ethernet ports lamp; 20 steps internal fixation points and stereo capture mode. Large LCD monitor for patient management; alignment, capture and
depending on mode review. Network ready and DICOM conform. Telemedicine ready. VISUCAM comes with the onboard functionality to
connect to FORUM Data Management system. FORUM allows real-time viewing of reports or images from supported
networked ZEISS and non-ZEISS instruments. FORUM supports bi-directional workflow for supported DICOM enabled
devices, reducing charting errors and increasing patient throughput.
yes internal digital sensor; Xenon flash no All-integrated design with onboard database system. Auto-flash, auto-focus, 3.3mm small pupil mode, external fixation
USB and ethernet ports lamp; 24 steps and stereo capture mode. Large LCD monitor for patient management; alignment, capture and review. Network ready
depending on mode and DICOM conform. Telemedicine ready. VISUCAM comes with the onboard functionality to connect to FORUM Data
Management system. FORUM allows real-time viewing of reports or images from supported ZEISS and non-ZEISS
instruments. FORUM supports bi-directional workflow for supported DICOM enabled devices, reducing charting errors and
increasing patient throughput.
FA option 2 USB 2.0; no flash yes Fully integrated imaging system that delivers the next g
eneration of ophthalmic visualization, photo documentation and
1 primary; ease of use with a new user interface, redesigned cart and ergonomic hand piece. This advanced system incorporates
1 Ethernet port DICOM compatibility and image annotation feature. Brilliant, full-color images can be captured for immediate
assessment of the retina and anterior chamber; digital images can also be sent electronically to the ophthalmologist
for immediate evaluation and longitudinal tracking over time. The RetCam 3 Digital Imaging System makes it possible
to facilitate ophthalmic care in the hospital NICU, PICU and operating room.
no 2 USB 2.0; no flash yes RetCam Shuttle enables ophthalmic imaging with a convenient, mobile system that can be easily maneuvered into
1 primary; tight spaces and transported to affiliate hospitals. The Shuttle system enables on-site or remote documentation
1 Ethernet port of the pediatric retina and pediatric or adult anterior chamber. Network capability allows transfer of images to any
networked system or to a physician for remote evaluation.
yes n/a n/a n/a Digital imaging for most mydriatic fundus camera; 5 MP CCR sensor; calibrated measurement tools; Auto Eye-Map
montage feature; DICOM-compliant; integrates with PACS and OphthaVision AXIS for side-by-side review of
images from different modalities.